Description
FOUR Fan, massive 440 CFM! Adjustable airflow, self balancing overhead ESD ionizer with built in emitter cleaners are built into the HDSL-1104 High Output ESD Ionizer. THE most ionic output for your money. Outstanding reliability. Perfect for large ESD work stations as well as packaging areas and more. High Output ESD Ionizer from United Static Control Products useful for massive ionization and ESD control. Great power for the money!
Features
- Outstanding quality, ISO manufactured!
- POWERFUL yet highly balanced output.
- Robust performance, VERY low maintenance.
- Certificate of compliance provided with each unit.
- +/- 5 volt steady state offset voltage balance!
- Built in emitter cleaning brushes easy to keep clean!
- Self adjusting circuitry, calibration typically not required.
- Easily controllable high output multi speed fans.
- CE Certified, One Year Warranty and built to last a lifetime!
- The HDSL-1104 meets or exceeds the recommended technical requirements of ANSI/ESD S 20.20-2014 tested in accordance with STM3.1.
HDSL-1104 High Output ESD Ionizer – Specifications
Download the Specifications / Cut Sheet for the HDSL-1104
Line Voltage: 110V/60Hz standard, 220V/50Hz optional.
Current Draw: Max 1.66 Amp, Min 0.83 Amp
Operating Temperature: 32 Deg F to 122 Deg F, (0 ~50°c)
Weight: 26.5 pounds (7.68kg)
Casing: powder coated aluminum
Dimensions: 46.5″ (L) x 6.10″ (W) x 4.33″ (H) inches
Air Volume: 180 to 440 CFM
Note: Maximum flow amount equals sum of foure fans at 100%.
Air Coverage: 28″ x 54″ (inches).
Recommended Distance from Work Surface: 24″ to 54″ (inches).
HDSL-1104 High Output ESD Ionizer – Extended Information
Our HDSL-1104 4 fan overhead ESD ionizer provides a massive (440 CFM) yet highly balanced (+/- 5 V) ionic output making it the perfect selection for large static control ESD workbenches, static free work areas, production lines, packaging and more. Unlike many ionizers that require contaminant free air and continual maintenance, the HDSL-1104’s steady-state, self balancing circuitry continuously adjusts to compensate for emitter point wear, line voltage fluctuations, variations in air particulate and velocity keeping maintenance to a minimum and performance at a maximum. Used by major companies world wide, the HDSL-1104 features ultimate ionic output (but no overhead lighting like our HDSL-003. It’s quiet, with fully adjustable airflow, long life tungsten emitters (typical life span five years and easy to replace) and a casing manufactured of a light weight aluminum alloy with a static dissipative powder coating (meticulous high tech finish).
Line Voltage | 110V/60Hz standard, 220V/50Hz optional |
---|---|
Current Draw | Max 1.66 Amp (fan high), Min 0.83 Amp (fan low) |
Operating Temperature | 32o F to 122o F, (0 ~50°c) |
Weight | 26.5 pounds (12 kg) |
Finish and casing material | Powder coated aluminum alloy |
Size | 46.5″ (L) x 6.10″ (W) x 4.33″ (H) inches |
Air volume output | Fan speed low: 180 CFM, Fan speed high: 440 CFM, Note: Flow amount equals sum of four fan operation. |
Air coverage | 28″ x 54″ (inches) |
Recommended distance from work surface | 24″ to 54″ (inches) |
Note
The following are overviews, please see manual (included with product) for full details.
Installation: The HDSL-1104 is an overhead unit designed to provide ideal coverage for control of electrostatics. Note: Do not insert objects into air intake or outlet grille and do not operate the HDSL-1104 High Output ESD Ionizer in inflammable or explosive environments. The HDSL-1104 ionizer should be affixed 24 to 54 inches above the work surface with center targeted directly over work area. This unit may also be positioned and operated vertically should conditions dictate. Avoid drafty locations such as that caused by air conditioning, heater outlets, etc.
Attachment to overhead supports: S hooks and chains may be used for mounting these ionizers to structurally sound ceilings or wire shelves. Chains and mounting hardware should have a minimum safe working load of at least 50 pounds. When mounting the unit to ceilings it is important to check state and local codes to insure compliance. These units are typically hung in the same fashion as an overhead light fixtures (independently attached to the overhead building superstructure). Attachment to suspended ceilings only are typically not compliant with local codes. Mounting to workbench overhead supports: These ionizers may be mounted to work bench overhead shelves and beams using the supplied side mounting bracket in conjunction with angle iron, bolt on L brackets etc. These ionizers may be used either horizontally or vertically.
HDSL-1104 High Output ESD Ionizer – Electrical Requirements
The HDSL-1104 High Output ESD Ionizer requires 110VAC /60Hz (standard) or 220VAC / 50Hz (optional) power. These units must be grounded. Each unit is supplied with standard US 3 prong male grounded power plug (standard). Do not modify the plug or use an ungrounded 3 prong receptacle. If an extension cord is required use heavy gauge fully grounded cords only.
Operating Procedure
Activate the SL-1104 overhead ionizing blower by turning the fan speed knob clockwise. The ionization indicator will illuminate and indicate the presence of ionized air. Airflow speed may easily be adjusted from 3% to 100% output utilizing the fan speed knob. The time required to neutralize electrostatic potential is dependent on the distance of the High Output ESD Ionizer to work surface, the voltage collected on the insulator and the speed of fans. When used in electronic assembly the ionized air stream should cover as much of the working area as possible. The constant flow of ionized air prevents items from developing an electrostatic potential and neutralizes electrostatic charges present on objects introduced to the airflow.
Routine Maintenance
Clean emitters points as needed. Inspect the points on occasion using a flashlight and magnifying glass. The points should be sharp and free of carbon build up and residues. To clean the ion emitter points press and turn the emitter cleaner knob (located in the center of each air outlet) clockwise one full turn and release the knob. The emitter points should always be sharp and not rounded at the point. Should these tips become rounded simply replace the emitter ring. Please Note: The typical emitter life is greater than 4 years. Replacement emitters rings are easy to install and available from United SCP. Periodically test the ionic output as indicated by your internal ESD program or ANSI/ESD S 20.20-2014, TR53, Air Ionizer Compliance Verification (discharge time and offset voltage).
UNITED ESD PROVIDES FREE SHIPPING ON SELECT ITEMS MARKED WITH “FREE SHIPPING”
IONIZERS
United SCP provides free shipping on all ESD Ionizers marked as “free shipping.” This offer is specifically limited to the lower 48 States. This offer is limited to us shipping standard freight and using a carrier of our choice. Should you wish to expedite your free shipping items please contact our sales team for a shipping quote by calling 719 676 3928 (option 1) or by email.